I used sharkbites in my baseboard hot-water heating. Can I use PEX pipe for compressed air applications? A quick way to do this is to use a soapy water solution; if there are any leaks, the bubbles will show you where they are. If it wasnt clean and smooth when it was originally inserted into the sharkbite fitting it might have been hard for the oring to seal or the teeth to seat properly, which may have in turn been the cause of failure. (However, when considering cost, it's important to consider labor and installation, too. Plus, it is faster to install than metal or rigid plastic and has fewer connections and fittings. Soldered = copper pipe fittings. ", http://www.ekowoodboilerblog.blogspot.com/, www.YouTube.com/user/hotandcoldtelevision. Orlan EKO 40, Forced Air Furnace HX - Sold to a good home. Reply 01-02-2014, 08:04 PM #2 HVAC_Marc They will not work with PVC or other types of piping. Water systems should not be allowed to freeze. Can SharkBite fittings be used with soft copper or rolled copper? PEX-A, which is a type of PEX, is a top choice for hydronic heating applications for so many reasons. Oxygen Barrier and PEX-AL-PEX tubing are intended for heating applications (radiant floor heat, baseboards, etc.) Are SharkBite fittings certified for hydronic heating applications? Learn more: NSF/ANSI Standard 61. The Pellet Mill - Pellet and Multifuel Stoves, Central Boiler OWB Overheat/Not Circulating Troubleshooting Help. What can I text my friend to make her smile? Happy to use pex - will I be able to join this to my copper system say if I cut it at where it hits the second floor then use pex to connect to the baseboard and fins? How can you tell the difference between PEX-A and PEX-B? Whether you're working with PEX, Copper, or CPVC, AquaLock has you covered . When it comes to strength, both Sharkbite fittings and soldering can create strong, watertight connections. Can I use PEX pipe for radiant or hydronic heat applications? Crimp rings go voer the pipe then are crimped down onto the fitting. Yes, SharkBite fittings can be used for hydronic heating applications if the temperature does not exceed 200F. of lead-free silver solder and bend it at 90 about 2 in. Free Shipping Policy excludes LTL Truck Deliveries and just a few oversized products. pressed= copper fittings with an O-ring seal that get pressed on the pipe = sharkbite that needs a special tool. JavaScript is disabled. Or is "expansion fitting" synonymous with a fitting that is 'pressed' ? . Soldered joints are permanent, and they create a seamless connection between the two pipes. So if youre using them for compressed air, make sure the pressure is not too high. Yes, SharkBite fittings can be used for hydronic heating applications if the temperature does not exceed 200F. I just kept my fittings a sufficient distance from the heat source (stove) so that the fitting did not exceed 240 via radaint heat transfer. Yes. PEX A Material: $0.35/foot 90 fittings: $1.00/each Sleeves: $0.15/each Tool: Milwaukee Automatic Expansion Tool, $250 FIP x 18 in. SharkBite brass push fittings are approved by IAPMO for underground applications as long the fitting is wrapped with silicone tape. Its a type of plastic that has been treated with chemicals to create stronger bonds between its molecules. Are SharkBite fittings approved for use behind-the-wall? Lots of stress around there between weight and future service etc. Read more about behind-the-wall applications. Perhaps not but just an observation. On the way I could hear a lot of water moving, so I got to thinking this was not a false alarm. Apollo PEX Lead-Free dezincification-resistant brass elbows are the premier low-cost solution for connections within a PEX piping system. The pipe has scratches or debris on the outside that is preventing the O-ring from getting a watertight seal. I did this for two reasons: after consulting the product guides for the particular brand of PEX I used with an oxygen barrier it did not say crimp rings were approved for use and because sharkbites are full-port whereas most PEX connections go inside the tube, which is already smaller diameter than their copper nominally-sized counterparts. Sharkbite fittings, on the other hand, rely on O-rings to create a . Sharbite Fittings are lead free so they can be used in Plumbing and Heating Systems. There is no need to solder or glue these fittings, and they can be used with both copper and plastic piping. They are more expensive than typlical copper fittings, but they are easy to install and can removed for other use. I used sharkbites in my baseboard hot-water heating. If you do this, you MUST use the PEX that has an oxygen barrier. Hold the elbow in one hand and the tube in the other hand. Can I install SharkBite PEX pipe near a heat source such as heating appliances or gas flue vents? If you have any more questions you can call tech . After they were gone, the connector literally just slipped off the pipe and shot water out. Upon opening the door, there was steam and water just rushing out near the hot water heater. This worried me so I put expansion loops in the heating lines (literally just looped and clipped a several foot diameter loop of PEX in the middle of the run to allow for expansion and contraction) but i have found they're not needed, at least for the application I have. (I'm not running that high now). Lead free DZR brass construction for durability and reliability ; Use-to-connect to any combination of copper or CPVC pipes ; Push-to-connect fittings require no solder, glue, unions, or tools Thats because these particular fittings are not approved for use with drinking water. So everyone can be a master plumber. I'm Roger Wakefield, The Expert Plumber, and welcome to my channel. Plumbing relies on gravity to move water through pipes, while air compressors rely on electrical power to compress and move air through hose lines. I know from the spec sheets that sharkbite fittings are good up to 200F, and that my output temp shouldn't be that high, but it seems a bit close to me. Corrosion increases dramatically at higher temperatures. All Rights Reserved. PEX pipe is more cost effective than copper. PEX pipe is flexible and can be navigated around obstacles. I'm an air compressor mechanic and a businessman. Sign in or register to get started. SharkBitefittings are only certified for potable water & radiant heating installations. However, there is a growing selection of DIYers who would disagree. Shark Bites are repair fittings, not for assembly of Near-Boiler piping. SharkBite Compression Straight Stop Valve SharkBite PEX pipe is a cross-linked polyethylene tubing that provides an excellent option for plumbing, radiant and hydronic systems in both residential and commercial plumbing applications. This is designed specifically for heating systems and has a metal liner inside to prevent air from permeating in. But, it won't improve the turn radius. I'm sure either way would work out for you. Type A pex is the only one that can be unkinked by application of heat from a heat gun. Can PEX pipe be heated and bent? To use SharkBite fittings, you simply have to push them into the ends of both pipes that you want to connect. PEX pipe can also be encased within a slab, which is commonly used for radiant floor heating. The SharkBite push-to-connect range is made from Lead Free DZR Brass and all products were converted as of October 2012." Oxygen Barrier and PEX-AL-PEX tubing are intended for heating applications (radiant floor heat, baseboards, etc.) This product includes 2 color coordinated crimp rings - the included black crimp ring is intended for PEX while the copper-colored crimp ring is for use on polybutylene pipe. Additionally, PEX is resistant to corrosion and will not degrade over time like some other materials. Because the SharkBite oxygen barrier PEX is flexible, the team could more easily handle it than rigid pipe, bending it and securing it quickly along the floor. Sharkbite fittings are for DIY'ers that don't know how to solder, or for temporary emergency fix's, or connecting pex to copper if you don't have the proper fittings on hand. Where is PEX pipe approved for plumbing use? If you continue to use this site we will assume that you are happy with it. Most hot water systems run great at 170-180. Enter a Melbet promo code and get a generous bonus, An Insight into Coupons and a Secret Bonus, Organic Hacks to Tweak Audio Recording for Videos Production, Bring Back Life to Your Graphic Images- Used Best Graphic Design Software, New Google Update and Future of Interstitial Ads. SharkBite Fittings are certified for potable water supply and hydronic heating applications. In this article, we'll cover the pros and cons, discuss the history, and share what . The SharkBite 1/2 inch x 3/8 inch Compression Angle Stop Valve was designed to be an industry standard, trusted by plumbers across the globe. Hands-on with the new System 76 Lemur Pro laptop, Connecting a Hydreon Infrared Rain Sensor to a ESP8266 (or Arduino or Raspberry Pi), A (medium-length) primer on energy, greenhouse gas, intermittency, and nuclear, The Total Solar Eclipse Experience in the Malheur National Forest, Making a cheap and simple barn-door star tracker with software tangent correction for astrophotography, The modern era passed through a cathode ray tube, Sending and receiving Morse code with a laser and a Raspberry Pi. They are those nifty little red and blue push-to-connect fittings that make working with copper pipe a lot easier. 9630 N Lombard St, Portland, OR 97203, United States. Orange PEX pipe is an oxygen barrier PEX pipe used only for hydronic heating applications. There was another connector like this as the inlet to the hydronic heating system. SharkBite is one common brand of stab-in fitting. While SharkBite is unquestionably a well-constructed product with a premium price to match, there are pros and cons. When water freezes, it expands and creates pressure that exceeds plumbing system pressure capabilities, i.e. Non-Barrier PEX is intended for hot and cold domestic water use. If you are new here, please review posting/commenting guidelines below. The Boiler Room - Wood Boilers and Furnaces, "If you can't be making money, you might as well be making fires. Learn more: American Water Works Association. Create an account to follow your favorite communities and start taking part in conversations. Although, the SharkBite Deburr & Gauge Tool is recommended for deburring and measuring the depth of the pipe. FREE SHIPPING ON ALL PEX TUBING OVER $99. Plus, they're a good option for wet repairs if a system is . SharkBite push-to-connect fittings are the core products within the SharkBite System, and provide the easiest and most dependable way to join PEX, copper, CPVC, HDPE or PE-RT pipe in any combination without solder, clamps, unions or glue. RWC I wonder why that thing is going off?. tubing, you'll only use about 1/2 in. PEX pipe is easier to install than rigid pipe, and it is available in long coils that can eliminate the need for extra fittings. So I staggered down to the garage on the first level. If youre in the market for a new compressed air system, you may have come across the term PEX. But what is PEX, and why is it a good choice for compressed air? It can also be used in domestic water applications because it meets the NSF/ANSI/CAN 61 standard. Those fittings should be soldered, pressed or screwed. But I thought maybe I should try out an ultrasonic clamp-on flow monitor on my main water pipe first. The tube liner can easily be removed by pulling it past the o-ring, with theaid of the SharkBite Disconnect Clip or Disconnect Tongs (both sold separately). Another method is to solder in a tee and a PEX supply adapter. Can I use SharkBite fittings for anything other than potable water and radiant heating (e.g, air, gas, oil, etc.) When SharkBite PEX pipe and fittings are used together, the labor . SharkBite fittings are compliant with the Uniform Plumbing Code (UPC), National Plumbing Code of Canada and the International Plumbing Code (IPC). SharkBite fittings can be used for hydronic heating applications if the temperature does not exceed 200F. Oxygen Barrier and PEX-AL-PEX tubing are intended for heating applications (radiant floor heat, baseboards, etc.) Add to Cart. I've got one on a hot water line and no leaks. You could also use the Sharbite Ball valves in this example. Plumbing fittings are not typically used for air compressors, as the two systems operate using different principles. That's 2 votes for pex now. Our self-fusing silicone tape that protects brass fittings from contaminants that can be found in ground conditions. There are a few different types of pipe that can be used for compressed air lines, but the most common is black iron pipe. Can I use SharkBite fittings for hydronic heating? I'm sure they are fine, but they don't have any 30 year examples of non-failure. Although you can use SharkBite fittings in inaccessible places, most plumbers recommend you use . Here are some of the benefits of using PEX for your compressed air system: There is no need to solder or glue these fittings, and they can be used with both copper and plastic piping. SharkBite fittings are certified for use underground, in behind the wall applications, and as a manufactured joint without access panels. Shark Bite fittings are not rated for heating, yet. Tube liners are not required when using SharkBite large diameter fittings with copper or CPVC. If you're using SharkBite fitting with hard drawn copper, make sure the copper is a K, L, or M type. First, only use SharkBite fittings with copper or PEX pipe. IN THE GARAGE! You can use push-fit fittings in both residential and commercial projects. Click Here for more info. I've looked at electric soldering a couple times for the same reasons. The following instructions will show you how to remove a Sharkbite fitting so that it can be reused. Not what they were designed for. Please make sure that the pipe is not exposed to direct UV rays. On Saturday morning at 4:19 am I was fast asleep. Also, if I use pex are Shark Bite fittings a good way to connect to the existing copper pipe. No, PEX pipe is not intended for compressed air applications. Can't honestly say I've ever tried to solder a copper to PEX fitting. I just had this little Fibaro Flood sensor guy, which worked great. This method doesn't require soldering, which can be a big time-saver. Is an "expansion fitting" yet another kind of fitting ?? Look at that! SharkBite Push-To-Connect fittings can withstand pressures and temperatures of up to 200 psi and 200F. I know many plumbers use Sharkbites and swear by them, and many home builders use them as well. Yes, PEX pipe can save money in numerous ways. I just installed SharkBite fittings with L pipe which is thicker as I have read several times not to use M with hot water because its too thin. You could also use the Sharbite Ball valves in this example. Something about them just makes me nervous. PEX is resistant to corrosion and chemical damage. We play games, we experiment, and we have FUN here, talking and learning about all things plumbing! Gear We Use:Coolest Clock Ever - https://amzn.to/31CjLkWMain camera - https://amzn.to/2RCyj1FLens for main and Second cameras - https://amzn.to/2SM7Second camera - https://amzn.to/2SdzfdQMy microphone - https://amzn.to/2FEvN8sXLR Interface - https://amzn.to/2RDqskjWireless Lav Mic - https://amzn.to/2HenuRpTripod to hold our camera - https://amzn.to/32aI7DjOur studio lights - https://amzn.to/2Zv2R6O*NOTE: This description contains affiliate links that allow you to find the items mentioned in this video and support the channel at NO COST TO YOU. Apollo PEX fittings are suitable for both potable water and hydronic heating systems. I touched it gently and it started dropping. PEX pipe does not require glue or cement, and can simply be joined with push-to-connect fittings, metal insert fittings, or plastic insert fittings for a watertight seal. the expansion fitting has a better chance of shrinking back down to its original configuration if it freezes as well, freezing could tend to push a crimp ring off or cut the tubing on the crimp ring. When combined with our push-to-connect fittings, manifolds, valves and other supplies, PEX pipe offers the fastest way to plumb any project. However, if you are connecting the large diameter fittings with either HDPE, PEX, PE-RT pipe, you will need the plastic insert. x 18 in. Yes. PEX-A: Peroxide This method employs organic peroxides that, when heated, generate reactive free radicals that splice PEX chains together during extrusion, PEX-B: Silane This method involves grafting a reactive silane molecule to the backbone of the polyethylene, PEX-C: Electron beam This method involves subjecting the extruded PE pipe to a dose of high-energy electrons. SharkBite fittings can be used for hydronic heating applications if the temperature does not exceed 200F. It is not required for copper or CPVC, however, it is not necessary to remove the tube liner from the fitting. Installing a radiant heating system is simplified with the SharkBite radiant heating installation kit. The answer is yes! Barrier PEX up through the floor to your new Panel Radiators, one under each window, will give you individual room control and most of your wall space back. This is a true story but is a single occurrence, I dont really know how likely this is to happen more. I would be very surprised if your system requires 200 degrees. Onix fittings require SqueezeTite Pliers and SelfTite clamps to make successful connections. PEX pipe is made from cross-linked HDPE (high density polyethylene). We dont recommend using a SharkBite fitting outside because sunlight can dry out the rubber O-ring and cause it to crack or split. How well do SharkBite joints hold up in freezing temperatures? Sharkbite may be fine in 30 years, but it may not be, too. Pex is flexible, making it easy to route through your facility. Thank goodness I had a traumatic house flood as a child and as a result had installed a little flood sensor. and Push (sharkbite) but that one has already bee defunked. Yes. Can PEX pipe be joined with solvent cement? Comparing PEX Connections. Priced $27.08 (compare at $28.50). If still having issues, don't hesitate to contact our support team. from the end to make it easier to solder around the joint. If the manufacturer rates the fitting for 200 and you never go over that, shouldn't be a problem. It may not display this or other websites correctly. Nice. You must push in a single, firm motion. Rotating the fittingwill not affect the integrity of the joint. Expansion is a collar that goes on the pipe then is expanded and shrinks back onto the fitting. If you think about it both copper press fitting and SharkBite or any grip fitting depend on the O ring for the seal. I'd put PEX on anything that isn't a temporary or exposed connection. Rated to 200 PSI and 200 Degree F, this is a great option for use in potable water and hydronic heating applications. A SharkBite connector with 1/2 copper pipe inserted. SharkBite PEX Barb fittings are compatible for potable water distribution and hydronic heating applications. Simple installation and ease of use make the SharkBite push-fit fittings and valves one of the fastest, easiest ways to plumb many residential or commercial jobs, and are easy to disconnect if needed. It has just begun, and the puddle was rapidly moving across the floor and soon covered most of it. Up-to-date pipe insertion depths can be found here. Yes. PEX can withstand high temperatures and pressures. I would probably insulate it myself. I think their heat rating is dependent on pressure as well as the material they are joining. If youre working with a potable water system, then you definitely dont want to use SharkBite fittings. f. That rating has plenty of play in it considering most hydronic systems do not exceed 180-200 range. The HDPE is melted and continuously extruded into a tube to form a high-performing pipe suitable for a variety of potable and non-potable plumbing applications. Plus, PEX pipe is flexible which makes it fast to install and requires fewer directional fittings. Welcome It looks like you're new here. But check with your plumbing inspector if you're planning to bury this connection in a wall or ceiling. The colors can be used to easily distinguish between hot and cold distribution lines. PEX pipe is cost-effective, flexible, durable and easy to install, making it a popular choice vs. copper and CPVC piping. Braided Stainless Steel Water Heater Connector with Integrated Ball Valve located in New Prague, MN in . What types of pipe can SharkBite fittings be used with? 62K views 4 years ago #homerepair In this video we show you how to replace an existing heating element with a new one using Shark Bite fittings. You may have even used them yourself on a plumbing project. x 100 ft. PEX is a great option for compressed air applications. What is the maximum temperature and pressure rating for SharkBite fittings? In another post I was reading that the overheat loop can get as hot as 210 F. That's above the rating for sharkbite fittings, so I'll stick with solder until well away from the boiler. It is flexible, resistant to scale and chlorine. Apollo PEX fittings may be used with copper crimp rings, stainless steel pinch clamps or stainless steel crimp sleeve (all sold separately). Picture 6: Sharbite Fittings example of how installed. What standards & codes do SharkBite fittings comply? Sign In There are two, actually three types of fitting for PEX pipe. I've come across an apparent contradiction.. background: I'm considering using oxygen-barrier PEX in an enhancement to my copper hydronic piping. What is the maximum temperature and pressure rating for SharkBite fittings? You pretty much have the right info. Hi Larry, yes, you can use PEX. Thermal memory allows the repair of accidental crimps in the PEX tubing through the means of a controlled heating source. I know lots of people on the internet totally live by push-to-connect plumbing fittings. PEX is semi-permeable, which means liquid can enter the pipe. Designed for potable water distribution as well as hydronic heating applications; pressed= copper fittings with an O-ring seal that get pressed on the pipe = sharkbite that needs a special tool. For 1/2-in. Browse our brass push products. SharkBite fittings canleak due to one of thesereasons: Review installation instructions to ensure you've followed the correct steps. Does SharkBite offer a warranty on its PEX plumbing system? As a follow up did you use sharkbite for your pex or soldered connections. Atube liner is required when using the SharkBite large diameter fittings in conjunction with PEX, PE-RT or HDPE pipe. Find answers to the most commonly asked questions about SharkBite PEX pipe. | Never again is my new rule. Nice. Push the tube into the elbow. PEX pipe doesnt require the use of glue or cement, can be air tested and can be installed in wet or dry conditions. Soldered = copper pipe fittings. Shark Bite fittings are not rated for heating, yet. Depends on the item. and Push (sharkbite) but that one has already bee defunked. Kink-Resistance PEX-A has the greatest resistance, PEX-B the lowest. Hello - Yes, brass SharkBite Push-to-Connect fittings are suitable for radiant/hydronic heating. Press question mark to learn the rest of the keyboard shortcuts. Can you use PEX for forced hot water heat? I use a special electric soldering clamp for all the soldering I do, since I work in old to very old structures where using a torch just isn't a good thing. Today I'm telling you why I don't use Sharkbites and why I don't let my plumbers use them either. SharkBitefittings can be rotated after installation. Flexibility PEX-A is the most flexible, allowing for it to be fastened by cold expansion, which allows the end to be fluted prior to inserting the fitting. Without the ferrule, there is potential for leakage. PEX pipe is cost-effective, flexible, durable and easy to install, making it a popular choice vs. copper and CPVC piping. Once youre satisfied that everything is secure, go ahead and turn on the compressor and enjoy the convenience of having SharkBite fittings in your shop! cost effective than copper. SharkBite fittings can be used for hydronic heating applications if the temperature does not exceed 200F. For 1/2" PEX with OD of 5/8", minimum bending radius is 8 x 5/8" = 5".