0000010312 00000 n Interconnector station, linked to Les Mandarins France via underground/under sea cable. usability. National Grid said the site had been evacuated, and there have been no reports of casualties. 0000006774 00000 n National Grid 2022/23 Half Year Results Statement - Company The blaze at the Sellindge converter station in Kent forced a shutdown of the high-voltage cable that brings electricity from France to the UK last month as energy markets rocketed to all-time. There are currently no reviews for this company. See the related streets of postcode TN256AH, nearby schools and more. This means that we may include adverts from us and third parties based on our knowledge of you. In early September, the GB power market balance began to tighten, with numerous generators and interconnector capacity undergoing planned maintenance ahead of winter - a typical situation during the autumn 'shoulder-month' period. The landing point for the subsea cable linking France to the UK is Folkestone, from where underground cables connect to the Sellindge converter station and then onto the UK's transmission station. A converter station converts electricity between Alternating Current (AC) and Direct Current (DC). The basic building block of the converter is the six-pulse bridge. HVDC | PDF | High Voltage Direct Current | Electrical Substation - Scribd According to data from the National Grid (LON: NG ), flows on the 2,000 megawatt (MW) IFA-1 cable were halted overnight, however, the IFA-2 cable is . Grid Solutions, a GE Renewable Energy business, serves customers globally with over 13,000 employees. Amperage is the number of atoms involved in the distance conveyance. View information about postcode TN25 6AH in Sellindge. Sellindge Converter Station Church Lane Sellindge Ashford Kent TN25 6AF. A large fire at a key substation in the UK has forced the shutdown of one of the most important power cables that import electricity from France. The National Grid Sub Station in Sellindge (Image: Google Maps) The National Grid has warned a Kent power plant will not be up and running again until 2023. House-sized transformer travelling through Kent to Sellindge The undersea section consists of eight 46km (29miles) long 270kV submarine cables, laid between Folkestone (UK) and Sangatte (France), arranged as two fully independent 1,000MW Bipoles, each operated at a DC voltage of 270kV. and begin my permanent role on-site at Sellindge. Fire Hits Key Power Converter Station Linking U.K. to France and industries worldwide with equipment, systems and services to bring power reliably and efficiently from the point of generation to Areva&hvdc PDF | PDF | Electrical Substation | High Voltage - Scribd It uses material from the Wikipedia article "HVDC Cross-Channel". The damaged interconnector in Sellindge, near Ashford, normally supplies 2 gigawatts (GW) of energy from France and is one of the UK's largest sources of foreign power. This does get around the limited direct links between Belgium and France. The village centre is eight miles (12 km) south-east of the town of Ashford. Sellindge Converter Station is an electrical substation in Ashford, Kent. Sign up to our daily newsletter for all the latest Kent stories and breaking news delivered straight to your inbox. [10] Repairs were completed by the end of February 2017. Sellindge was commissioned in 1986 and has many distributed control and monitoring systems. 0000003997 00000 n . Typically over five years to design, procure and build an HVDC converter stationdelivered in 16 Liked by Rajasekar Sampath. connection of renewable and distributed energy resources to the grid. National Grid fire: Electricity halted from France till Oct as station Gas and power prices jumped. Fire-damaged power link will be out for six months, says National Grid Proven technologies and world-class partners. 0000001916 00000 n Tel: +254722353414. Under the terms of a contract with British grid operator National Grid (LON:NG), Siemens will deliver, install and commission four 400-kV and 315 MVA transformers for the Sellindge converter station in England. Meanwhile, Ofgem has warned households face another steep increase in energy bills from next April when the new price cap comes into force. Huge fire breaks out at National Grid station as staff evacuated - Metro trailer <<431B830FD85F402ABA804851D03E7DCD>]/Prev 502951>> startxref 0 %%EOF 102 0 obj <>stream National Grid Sellindge HVDC Convertor Stations, life extension of the control and monitoring systems. Supportable for the next 10 years, the system is operationally future-proofed to ensure the integration of IFA1 with IFA2, with clear upgrade pathways and backwards compatibility to optimise system longevity. This railway station is located on a distance of 6.2 km. accelerate the energy transition. 0000094349 00000 n s{\e5a`XXb6Nn=3LUk+2=_Z*b3WE{Z4k 6t^UxYlaM It would have been an even bigger exporter but for capacity outages on IFA1 linked to the fire at the Sellindge converter station over a year ago. Map Directions Satellite Photo Map Type: Electrical substation Category: industry It comes as the UK has been hit with record energy prices after a global gas market surge raised the cost of running gas power plants, which has been compounded by a string of outages and low wind speeds. However, France imports energy as needed during the winter to meet demand, or when there is low availability of hydroelectric power. The first 400 kV substations in Scotland were commissioned in 1972 associated with the line from Hunterston, Ayrshire to Neilston, Renfrewshire. These candidates have been chosen based on the following criteria: TN25 6AH postcode in Sellindge - postcode TN256AH Capula has been awarded the design, manufacture, test, install and commission of the Supervisory Control and Data Acquisition (SCADA) System for National Grids Ventures Sellindge High Voltage Direct Current (HVDC) converter substation. Consisting of new equipment, upgrading of obsolete, and utilising existing control systems, Capula will integrate these technologies into one control room SCADA and new electronic mimic screen. Over the RIIO-T1 Regulatory Period, we are one of the largest suppliers of Capula has been subcontracted by AMEY to deliver a full turnkey, cyber secure protection and control solution. Siemens to supply transformers for UK-France link Liked by Rajasekar . HVDC Systems - GE Grid Solutions The first HVDC Cross-Channel scheme was built by ASEA and went into service in 1961,[3] between converter stations at Lydd in England (next to Dungeness Nuclear Power Station) and Echinghen, near Boulogne-sur-Mer, in France. Supportable for the next 10 years, the system is operationally future-proofed to ensure the integration of IFA1 with IFA2, with clear upgrade pathways and backwards compatibility to optimise system longevity. MaxSine is a Modular Multi-Level Converter (MMC) consisting of multiple submodules connected in series to form a chain-circuit. About Interconnectors - Elexon BSC The offshore converter platform will be the heart of the wind farm and will comprise a 10,000 tonne topside attached to a 7,000 tonne jacket foundation piled into the seabed. 0000091737 00000 n The Sellindge converter station joins Interconnexion France-Angleterre to the 2,000 MW HVDC interconnector which links the British and French electricity transmission systems. GE is globally recognized for designing, manufacturing and delivering customized HVDC solutions for utilities worldwide. HVDC converter stations | Hitachi Energy National Grid, which owns the 2,000 megawatt cable, expects half of its capacity to return to service on . This is done by means of high-power, high-voltage electronic semiconductor valves. 0000012331 00000 n As always you can unsubscribe at any time. It plays a vital role, increasing the UKs energy security, reliability and capacity by connecting with the French electricity transmission network to bring a number of benefits, including lower cost electricity, increased access to low-carbon energy and improved security of supply. Converter station footprint (relative size) 200m x 120m x 22m (100%) 120m x 60m x 22m (~40%) Conversion losses (per converter end) 0.7% to 0.8% of transmitted power 1% of DC voltage Up to 800kV Whilst repairs were undertaken there was considerable down time on the circuit resulting in a loss of trading. 0000005111 00000 n The fire service said four crews remained at the seen "dampening down remaining hot spots" at 14:45 BST. 0000084241 00000 n The cable is also known as IFA,[1] [2] and should not be confused with the new IFA-2, another interconnect with France that is three times as long but only half as powerful. A power cable running under the English Channel was "not operating" after the fire, the National Grid said. 0000008823 00000 n At conservative gathering, Trump is still the favourite. 0000091377 00000 n frequency: 50;0: location: outdoor: name: Sellindge Converter Station: operator: National Grid plc: Alstom signs contract with National Grid to test a more environmentally Voltage levels of 800kV and above have been considered but no converter stations have been built at these voltage levels. Indeed, by 1984 the circuit was disconnected from the Main Transmission System. 20,000 Volts Under The Sea - Climate Scepticism Something went wrong, please try again later. 0000005872 00000 n Please note that there might be constraints on site display and AC is used in each country's transmission system, while DC is used for sending electricity long distances along the subsea cables. 0000012629 00000 n Imports through the interconnector have generally been around the highest possible level, given the capacity of the link. on the rate of change of the 400 kV RMS voltage at Sellindge converter station calculated without the dynamic compensa-tion. In common with the 1961 scheme, there is no provision to permit neutral current to flow through the sea. You can also sign up to our website and comment on our stories by pressing here and signing in. The order includes the supply, installation and commissioning of the transformers for the Sellindge converter station in England. hb```b``=) B@16#- 0000002512 00000 n "During his time with Siemens as a project management professional, Tomek developed comprehensive understanding and mastery of how small and large (1m - 100m+) complex projects are structured, controlled & driven, and subsequently has been exposed to the various challenges in their delivery. 0000005086 00000 n HVDC systems utilize power electronics technology to convert AC and DC voltage and are ideal for supporting existing systems or building new power highways. Dear Customers, We wish to update you on the major incident that occurred at IFA yesterday. 0000011967 00000 n 0000056347 00000 n National Grid, Electrical Distribution Companies In Ashford - Scoot [3] From 1958 the super-grid and its substations were built by the Transmission Project Group within the Central Electricity Generating Board and included architects and landscape architects. The shutdown came at a time of high prices and supply shortage in the UK electricity . 0000015608 00000 n Sellindge was commissioned in 1986 and has many distributed control and monitoring systems. The new units will replace the old transformers at the site, significantly improving the system's reliability. Home > Systems & Services > High Voltage Direct Current Systems. We electrify the world with advanced grid technologies and 8o0 5 endstream endobj 50 0 obj <>>> endobj 51 0 obj <>/Font<>/ProcSet[/PDF/Text/ImageC]/Properties<>/XObject<>>>/Rotate 0/TrimBox[0.0 0.0 595.276 841.89]/Type/Page>> endobj 52 0 obj <> endobj 53 0 obj <>stream GEs latest fully-digital industrial HVDC Control System is designed to enable utilities to efficiently move more power further with a higher degree of controllability, thus improving power quality and maximizing overall grid performance. The equipment occasionally faults, causing capacity to drop: in a bad year, this might happen several times. description: Interconnector station, linked to Les Mandarins France via underground/under sea cable. Russian minister laughed at for Ukraine war claims. In order to return the site safely to service, the Grid says that "extensive work" must be carried out. The time delays were We use your sign-up to provide content in the ways you've consented to and improve our understanding of you. . Twelve fire crews were sent to the site in Sellindge near Ashford on Wednesday,. 0000018925 00000 n Way History: Sellindge Converter Station (23281217) Version #15 Power mapping Edited almost 2 years ago by Russ; Changeset #100435100; Tags. This HVDC-link is 73 km (45 miles) long in route, with 70 km (43 miles) between the two ends. This website is using a security service to protect itself from online attacks. We deliver unparalleled efficiency and safety, vital to the energy needs of GB and the north-western European Region. Sellindge was commissioned in 1986 and has many distributed control and monitoring systems. Energy prices soar after fire shuts down key electricity cable in - MSN site. The National Grid has warned a Kent power plant will not be up and running again until 2023. In order to keep the disturbances of the magnetic compasses of passing ships as small as possible, a bipolar cable was used. Sellindge Converter Station Map - Electrical substation - Ashford National Grid initially said the 1000MW (megawatts) of capacity would be unavailable until 13 October this year but in an update later pushed the date back to 27 March 2022. The twelve-pulse bridge is composed of 12 "valves" each of which may contain many series-connected thyristors in order to achieve the DC rating of the HVDC scheme. Or by navigating to the user icon in the top right. The British landing point for the subsea cables is near Folkestone, Kent, from where underground cables connect to Sellindge converter station and then on to the UK transmission system. . Fire cuts British power imports adding to supply squeeze - Yahoo! Please enable Electricity is converted from alternating current (AC) to direct current (DC) and vice versa in a converter station. Twelve fire crews were sent to the site in Sellindge near Ashford on Wednesday, Kent Fire and Rescue Service said. The HVDC link connects France and England and makes it possible to efficiently exchange energy in both directions. National Grid confirms fire at IFA interconnector site in Sellindge, UK Fire shuts one of UK's most important power cables in midst of supply The electricity is then transported as Direct Current via high voltage transmission lines over distances of up to several thousands of kms. The landing point for IFA 1 is Folkestone, from where underground cables connect to the Sellindge converter station and then onto the UK's transmission station. IFA Availabilty Update. With over 130 years of pioneering experience, GE offers two HVDC technologies, Line Commutated Converters (LCC) and Voltage Source Converters (VSC), to support a broad range of applications and deployable in different schemes including overhead line (point to point), back to back, submarine/land cable and offshore. The fire started at the National Grid site in Sellindge, Kent, in the early hours (Picture: Google) A fire erupted at a key National Grid station . We deliver unparalleled efficiency and safety, vital to the energy needs of GB and the north-western European Region. 0000063902 00000 n The picture shows the 400 kV HVDC transformers. New gas boilers could be banned within a decade 0000005589 00000 n In September 2021, a major fire at the Sellindge converter station led to the shutdown of the link. 2 The 'Tariff Meters' and associated current and voltage transformers shown on the 11kV side of 400/11kV station transformers (Tx 1 and Tx 4) in Attachment B. ISG 195/05 This latest project aims to support the extension of the operational life of the converter station through a refurbishment programme, with a focus on ensuring interoperability of legacy and the latest control systems. 62.171.130.70 OpenStreetMap is a map of the world, created by people like you and free to use under an open license. The blaze at the Sellindge converter station in Kent forced a shutdown of the high-voltage cable that brings electricity from France to the UK last month as energy markets rocketed to all-time highs amid global energy supply difficulties. Sellindge Converter Station. Capula will be involved in an important part of the refurbishment of the converter station control room, with the replacement of the SCADA system. Siemens to provide transformers for HVDC link between England and A recent report from the National Grid revealed that the UK would face a tighter margin between supply and demand for electricity supply this winter - but indicated there was enough capacity to keep the lights on. 0000008142 00000 n 01303 815200. Cookie policy. At its core will be the introduction of new protection solutions supported by As part of the EDF Group, Capula has supported many EDF programmes across their Generation, Customer, Renewables and International businesses delivering support right across the EDF energy mix. The GB landing point for the sub-sea cables is near Folkestone, Kent, from where underground cables connect to Sellindge converter station and then onto the GB transmission system. National Grid PLC National Grid 2022/23 Half Year Results Statement Follow BBC South East on Facebook, on Twitter, and on Instagram. I am excited to be working on such a technically challenging project and delighted to now be offering National Grid Ventures our engineering services maximising availability and uptime while controlling total lifetime cost. The GB landing point for the sub-sea cables is near Folkestone, Kent, from where underground cables connect to Sellindge converter station and then onto the GB transmission system. Copyright OpenStreetMap and contributors, under an open license. Although each station includes an earth electrode, this is used only to provide a neutral reference, and only one of the two electrodes is connected at a given time so that there can be no current flow between them. 0000009717 00000 n 0000064625 00000 n Rajasekar Sampath - Cyber Security Consultant - National Grid | LinkedIn The increase was principally driven by an additional 2.5 months of UK Electricity Distribution ownership; higher investment across both New York and New England, including the start of our upstate. 0000015525 00000 n A fire at a National Grid site has shut down a power cable linking electricity supplies between the UK and France. We also may change the frequency you receive our emails from us in order to keep you up to date and give you the best relevant information possible. 2023 BBC. Sellindge Converter Station Jonathan Billinger cc-by-sa/2.0 0000091092 00000 n Click to reveal Winter blackout fears after substation fire cuts off French power Major components of the HVDC converter station (single line diagram You are either using a browser that does not support JavaScript, or you have disabled JavaScript. Railway stations nearby postcode TN25 6AH. 0000007335 00000 n 0000013162 00000 n It forms a high voltage direct current (HVDC) bridge for the transmission of 2,000MW of electricity. An aerial photo shows the damage after the electricity interconnector fire at Sellindge in Kent A further 1000MW planned outage will be in place until 25 September. This scheme was equipped with mercury-arc valves, each having four anodes in parallel.[4]. As an example, poster "It Doesn't Add Up" identified on here recently a situation where the exact same volume of electricity was simultaneously being imported and exported from the same point (Sellindge Converter Station) over the Interconnector France Angleterre 1 and the ElecLink (through the Channel Tunnel). Ignite Nov 2022 by ASFPIGNITE - Issuu The company - which owns energy infrastructure like overhead and underground power cables - said there would be a reduction in the amount of electricity available to the network until 13 October following the fire. Capula has been awarded the design, manufacture, test, install and commission of the Supervisory Control and Data Acquisition (SCADA) System for National Grids Ventures Sellindge High Voltage Direct Current (HVDC) converter substation.